Product Description
Crownwell Oil-Injected Rotary Screw Compressors
CWD 7-400 & CWD 7-400 PM
Power output: 7-400 kW / 10-500 hp
Delivery rate: 0.8-71.2 m3/min / 28-2514 cfm
Pressure range: 7-13 bar / 100-190 psig
CROWNWELL COMPRESSOR – HIGHEST STHangZhouRD
SIMPLICITY BUT NOT SIMPLE
For 3 generations, customers from mechanical engineering, industry and trade have relied on CHINAMFG know-how when it comes to plHangZhou, developing and manufacturing compressed air systems. They are fully aware of the fact that CHINAMFG AIR is more than just ordinary compressed air: utmost safety, outstanding efficiency, excellent quality, maximized flexibility along with dependable service are the ingredients to transform CHINAMFG AIR into air to work with – in China, in Asia and in more than 102 countries around the world.
The III generation, the basis for economical compressed air production
The Know-How
More than decades of know-how in manufacturing for the compressed air market. World wide knowledge in different compressed air applications have guided the development of customer specified stationary screw compressors.
Technical Advancement for your Benefit
The advantage of CHINAMFG lies in its simplified construction. Fewer components are utilized. This means a 60% reduction in main and wearing parts and over 70% fewer pipes and connections. In turn, this greatly reduces the risk of leakages, making the system environmentally friendly. Safe direct drive operation without V-belt transmission.
The CHINAMFG CHINAMFG works in the following way:
Ambient air is drawn through the intake filter and the multifunctional control system into the CHINAMFG block. This block consists of a pair of screw rotors. The main rotor, driven by an electric motor, takes the secondary rotor with it. The air is drawn in by the rotation of both of the interlocking rotors and is continually compressed. During rotation, coolant is injected into the rotors and forms a hydrostatic film between the main and secondary rotors. The function of the coolant is to seal the rotors, lubricate the bearings and adsorb the compression heat. Before compressed air leaves the compressor ( at 80 ºC approx.) it is separated from the coolant before being cooled in the aftercooler to approx.. 8ºC to 12ºC above the ambient temperature. The coolant then passes to the thermostatic control block and filter, before entering the cooler where it is cooled from approx.. 80ºC down to 50ºC. It is then injected back into the CHINAMFG block.
Features:
Direct drive via flexible coupling.
Fully encapsulated CHINAMFG CHINAMFG block.
Standard electric motor Protection Index IP23 and IP54.
User friendly service access.
Top quality, washable, oil resistant sound insulation.
Ready for operation, prewired and fully enclosed.
With operating mode selector switch Automatic-Off-Continuous.
Centrally mounted cooling fan provided for compressed air and lubricant coolers.
Compact and neat cabinet design.
Optional Equipment:
Sense of rotation
Multiple unit control with automatic base load selection
Full motor protection
Mains isolator switch for wall mounting
Beyond these features we offer a wide choice of compressed air accessories in reference to our compressor product range.
Energy Recovery Systems CROWNWELL-THERM
Compressed Air Filters
Compressed Air Dryers
Condensate Traps
Oil-Water Separators
Compressed Air Receivers
Crownwell OIL-INJECTED FIXED SPEED COMPRESSOR
TECHNICAL SPECIFICATIONS CWD 7-400
(7.5-400kW / 10-500hp)
| Model | Motor Power kW / hp |
Free Air Delivery m3/min |
Noise Level dB(A) |
Dimension L * W * H mm |
Weight Kg |
|||
| 7barg | 8barg | 10barg | 13barg | |||||
| CWD7 | 7.5 / 10 | 1.3 | 1.2 | 1.0 | 0.8 | 66 | 880*700*920 | 240 |
| CWD11 | 11 / 15 | 1.7 | 1.6 | 1.4 | 1.2 | 68 | 1080*750*1000 | 400 |
| CWD15 | 15 / 20 | 2.5 | 2.3 | 2.1 | 1.9 | 68 | 1080*750*1000 | 420 |
| CWD18 | 18.5 / 25 | 3.2 | 3.0 | 2.7 | 2.4 | 68 | 1280*850*1160 | 550 |
| CWD22 | 22 / 30 | 3.8 | 3.6 | 3.2 | 2.8 | 68 | 1280*850*1160 | 580 |
| CWD30 | 30 / 40 | 5.3 | 5.0 | 4.5 | 4.0 | 68 | 1280*850*1160 | 600 |
| CWD37 | 37 / 50 | 6.8 | 6.2 | 5.6 | 5.0 | 68 | 1400*1000*1290 | 800 |
| CWD45 | 45 / 60 | 8.0 | 7.3 | 7.0 | 5.9 | 72 | 1400*1000*1290 | 850 |
| CWD55 | 55 / 75 | 10.1 | 9.5 | 8.7 | 7.8 | 72 | 1800*1230*1570 | 1660 |
| CWD75 | 75 / 100 | 13.6 | 12.8 | 12.3 | 10.2 | 72 | 1800*1230*1570 | 1800 |
| CWD90 | 90 / 125 | 16.2 | 15.5 | 14.0 | 12.5 | 72 | 1800*1230*1570 | 1900 |
| CWD110 | 110 / 150 | 21.2 | 19.8 | 17.8 | 15.5 | 72 | 2400*1470*1840 | 2500 |
| CWD132 | 132 / 180 | 24.5 | 23.2 | 20.5 | 17.8 | 75 | 2400*1470*1840 | 2700 |
| CWD160 | 160 / 215 | 28.8 | 27.8 | 25.0 | 22.4 | 75 | 2400*1470*1840 | 3000 |
| CWD185 | 185 / 250 | 32.5 | 31.2 | 28.0 | 25.8 | 75 | 3150*1980*2150 | 3500 |
| CWD200 | 200 / 270 | 36.0 | 34.3 | 30.5 | 28.0 | 82 | 3150*1980*2150 | 4000 |
| CWD250 | 250 / 350 | 43.0 | 41.5 | 38.2 | 34.9 | 82 | 3150*1980*2150 | 4500 |
| CWD315 | 315 / 400 | 51.0 | 50.2 | 44.5 | 39.5 | 82 | 3150*1980*2150 | 6000 |
| CWD355 | 355 / 450 | 64.0 | 61.0 | 56.5 | 49.0 | 84 | 3150*1980*2150 | 6500 |
| CWD400 | 400 / 500 | 71.2 | 68.1 | 62.8 | 52.2 | 84 | 3150*1980*2150 | 7200 |
- Unit performance measured according to ISO 1217, Annex C, Edition 4 (2009)
Reference conditions:
-Relative humidity 0%
-Absolute inlet pressure: 1 bar (a) (14.5 psi)
-Intake air temperature: 20°C, 68°F
- Noise level measured according to ISO 2151:2004, operation at max. operating pressure and max. speed; tolerance: ±3 dB(A)
Crownwell OIL-INJECTED PERMANENT MAGNET COMPRESSOR
TECHNICAL SPECIFICATIONS CWD 7-400 PM
(7.5-400kW / 10-500hp)
| Model | Motor Power kW / hp |
Free Air Delivery m3/min |
Noise Level dB(A) |
Dimension L * W * H mm |
Weight Kg |
|||
| 7barg | 8barg | 10barg | 13barg | |||||
| CWD7 PM | 7.5 / 10 | 1.3 | 1.2 | 1.0 | 0.8 | 66 | 760*700*920 | 200 |
| CWD11 PM | 11 / 15 | 1.7 | 1.6 | 1.4 | 1.2 | 68 | 980*750*1000 | 350 |
| CWD15 PM | 15 / 20 | 2.5 | 2.3 | 2.1 | 1.9 | 68 | 980*750*1000 | 360 |
| CWD18 PM | 18.5 / 25 | 3.2 | 3.0 | 2.7 | 2.4 | 68 | 1120*850*1160 | 500 |
| CWD22 PM | 22 / 30 | 3.8 | 3.6 | 3.2 | 2.8 | 68 | 1120*850*1160 | 520 |
| CWD30 PM | 30 / 40 | 5.3 | 5.0 | 4.5 | 4.0 | 68 | 1120*850*1160 | 550 |
| CWD37 PM | 37 / 50 | 6.8 | 6.2 | 5.6 | 5.0 | 68 | 1280*1000*1290 | 750 |
| CWD45 PM | 45 / 60 | 8.0 | 7.3 | 7.0 | 5.9 | 72 | 1280*1000*1290 | 780 |
| CWD55 PM | 55 / 75 | 10.1 | 9.5 | 8.7 | 7.8 | 72 | 1800*1230*1570 | 1600 |
| CWD75 PM | 75 / 100 | 13.6 | 12.8 | 12.3 | 10.2 | 72 | 1800*1230*1570 | 1800 |
| CWD90 PM | 90 / 125 | 16.2 | 15.5 | 14.0 | 12.5 | 72 | 1800*1230*1570 | 1900 |
| CWD110 PM | 110 / 150 | 21.2 | 19.8 | 17.8 | 15.5 | 72 | 2400*1470*1840 | 2500 |
| CWD132 PM | 132 / 180 | 24.5 | 23.2 | 20.5 | 17.8 | 75 | 2400*1470*1840 | 2700 |
| CWD160 PM | 160 / 215 | 28.8 | 27.8 | 25.0 | 22.4 | 75 | 2400*1470*1840 | 3000 |
| CWD185 PM | 185 / 250 | 32.5 | 31.2 | 28.0 | 25.8 | 75 | 3150*1980*2150 | 3500 |
| CWD200 PM | 200 / 270 | 36.0 | 34.3 | 30.5 | 28.0 | 82 | 3150*1980*2150 | 4000 |
| CWD250 PM | 250 / 350 | 43.0 | 41.5 | 38.2 | 34.9 | 82 | 3150*1980*2150 | 4500 |
| CWD315 PM | 315 / 400 | 51.0 | 50.2 | 44.5 | 39.5 | 82 | 3150*1980*2150 | 6000 |
| CWD355 PM | 355 / 450 | 64.0 | 61.0 | 56.5 | 49.0 | 84 | 3150*1980*2150 | 6500 |
| CWD400 PM | 400 / 500 | 71.2 | 68.1 | 62.8 | 52.2 | 84 | 3150*1980*2150 | 7200 |
- Unit performance measured according to ISO 1217, Annex C, Edition 4 (2009)
Reference conditions:
-Relative humidity 0%
-Absolute inlet pressure: 1 bar (a) (14.5 psi)
-Intake air temperature: 20°C, 68°F
- Noise level measured according to ISO 2151:2004, operation at max. operating pressure and max. speed; tolerance: ±3 dB(A)
- PM-Permanent Magnet
Crownwell TWO-STAGE OIL-INJECTED COMPRESSOR
TECHNICAL SPECIFICATIONS CWD 7-400 PM
(7.5-400kW / 10-500hp)
| Model | Motor Power kW / hp |
Free Air Delivery m3/min |
Noise Level dB(A) |
Dimension L * W * H mm |
Weight Kg |
|||
| 7barg | 8barg | 10barg | 13barg | |||||
| CWD15-2S | 15 / 20 | 3.0 | 2.9 | 2.4 | 2.2 | 68 | 1480*850*1180 | 780 |
| CWD18-2S | 18.5 / 25 | 3.6 | 3.5 | 2.9 | 2.5 | 68 | 1480*850*1180 | 800 |
| CWD22-2S | 22 / 30 | 4.2 | 4.1 | 3.5 | 3.2 | 68 | 1480*850*1180 | 820 |
| CWD30-2S | 30 / 40 | 6.5 | 6.4 | 4.9 | 4.2 | 68 | 1720*1110*1480 | 1080 |
| CWD37-2S | 37 / 50 | 7.2 | 7.1 | 6.3 | 5.4 | 68 | 1720*1110*1480 | 1100 |
| CWD45-2S | 45 / 60 | 9.8 | 9.7 | 7.8 | 6.5 | 72 | 1720*1110*1480 | 1120 |
| CWD55-2S | 55 / 75 | 12.8 | 12.5 | 9.6 | 8.6 | 72 | 2100*1350*1720 | 2080 |
| CWD75-2S | 75 / 100 | 17.5 | 16.5 | 12.5 | 11.2 | 72 | 2100*1350*1720 | 2100 |
| CWD90-2S | 90 / 125 | 20.8 | 19.8 | 16.9 | 14.3 | 72 | 2460*1700*1900 | 3280 |
| CWD110-2S | 110 / 150 | 24.5 | 23.5 | 19.7 | 17.6 | 72 | 2460*1700*1900 | 3480 |
| CWD132-2S | 132 / 180 | 30.0 | 28.0 | 23.5 | 19.8 | 75 | 2900*1800*2571 | 3980 |
| CWD160-2S | 160 / 215 | 34.5 | 33.6 | 30.0 | 23.8 | 75 | 2900*1800*2571 | 4280 |
| CWD185-2S | 185 / 250 | 41.0 | 38.4 | 32.5 | 28.6 | 75 | 3800*1980*2150 | 5450 |
| CWD200-2S | 200 / 270 | 44.6 | 43.0 | 38.5 | 32.8 | 82 | 3800*1980*2150 | 5600 |
| CWD220-2S | 220 / 300 | 48.6 | 47.0 | 41.0 | 38.0 | 82 | 3800*1980*2150 | 6500 |
| CWD250-2S | 250 / 350 | 55.0 | 54.0 | 46.0 | 40.0 | 82 | 3800*1980*2150 | 6600 |
- Unit performance measured according to ISO 1217, Annex C, Edition 4 (2009)
Reference conditions:
-Relative humidity 0%
-Absolute inlet pressure: 1 bar (a) (14.5 psi)
-Intake air temperature: 20°C, 68°F
- Noise level measured according to ISO 2151:2004, operation at max. operating pressure and max. speed; tolerance: ±3 dB(A)
- 2S-Two Stage
| Lubrication Style: | Lubricated |
|---|---|
| Cooling System: | AC Cooling and Air Cooling |
| Power Source: | AC Power |
| Customization: |
Available
|
|
|---|
.shipping-cost-tm .tm-status-off{background: none;padding:0;color: #1470cc}
|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
|---|
| Payment Method: |
|
|---|---|
|
Initial Payment Full Payment |
| Currency: | US$ |
|---|
| Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
|---|
.webp)
What role do air dryers play in compressed air systems?
Air dryers play a crucial role in compressed air systems by removing moisture and contaminants from the compressed air. Compressed air, when generated, contains water vapor from the ambient air, which can condense and cause issues in the system and end-use applications. Here’s an overview of the role air dryers play in compressed air systems:
1. Moisture Removal:
Air dryers are primarily responsible for removing moisture from the compressed air. Moisture in compressed air can lead to problems such as corrosion in the system, damage to pneumatic tools and equipment, and compromised product quality in manufacturing processes. Air dryers utilize various techniques, such as refrigeration, adsorption, or membrane separation, to reduce the dew point of the compressed air and eliminate moisture.
2. Contaminant Removal:
In addition to moisture, compressed air can also contain contaminants like oil, dirt, and particles. Air dryers help in removing these contaminants to ensure clean and high-quality compressed air. Depending on the type of air dryer, additional filtration mechanisms may be incorporated to enhance the removal of oil, particulates, and other impurities from the compressed air stream.
3. Protection of Equipment and Processes:
By removing moisture and contaminants, air dryers help protect the downstream equipment and processes that rely on compressed air. Moisture and contaminants can negatively impact the performance, reliability, and lifespan of pneumatic tools, machinery, and instrumentation. Air dryers ensure that the compressed air supplied to these components is clean, dry, and free from harmful substances, minimizing the risk of damage and operational issues.
4. Improved Productivity and Efficiency:
Utilizing air dryers in compressed air systems can lead to improved productivity and efficiency. Dry and clean compressed air reduces the likelihood of equipment failures, downtime, and maintenance requirements. It also prevents issues such as clogging of air lines, malfunctioning of pneumatic components, and inconsistent performance of processes. By maintaining the quality of compressed air, air dryers contribute to uninterrupted operations, optimized productivity, and cost savings.
5. Compliance with Standards and Specifications:
Many industries and applications have specific standards and specifications for the quality of compressed air. Air dryers play a vital role in meeting these requirements by ensuring that the compressed air meets the desired quality standards. This is particularly important in industries such as food and beverage, pharmaceuticals, electronics, and automotive, where clean and dry compressed air is essential for product integrity, safety, and regulatory compliance.
By incorporating air dryers into compressed air systems, users can effectively control moisture and contaminants, protect equipment and processes, enhance productivity, and meet the necessary quality standards for their specific applications.
.webp)
What are the environmental considerations when using air compressors?
When using air compressors, there are several environmental considerations to keep in mind. Here’s an in-depth look at some of the key factors:
Energy Efficiency:
Energy efficiency is a crucial environmental consideration when using air compressors. Compressing air requires a significant amount of energy, and inefficient compressors can consume excessive power, leading to higher energy consumption and increased greenhouse gas emissions. It is important to choose energy-efficient air compressors that incorporate features such as Variable Speed Drive (VSD) technology and efficient motor design, as they can help minimize energy waste and reduce the carbon footprint.
Air Leakage:
Air leakage is a common issue in compressed air systems and can contribute to energy waste and environmental impact. Leaks in the system result in the continuous release of compressed air, requiring the compressor to work harder and consume more energy to maintain the desired pressure. Regular inspection and maintenance of the compressed air system to detect and repair leaks can help reduce air loss and improve overall energy efficiency.
Noise Pollution:
Air compressors can generate significant noise levels during operation, which can contribute to noise pollution. Prolonged exposure to high noise levels can have detrimental effects on human health and well-being and can also impact the surrounding environment and wildlife. It is important to consider noise reduction measures such as sound insulation, proper equipment placement, and using quieter compressor models to mitigate the impact of noise pollution.
Emissions:
While air compressors do not directly emit pollutants, the electricity or fuel used to power them can have an environmental impact. If the electricity is generated from fossil fuels, the associated emissions from power plants contribute to air pollution and greenhouse gas emissions. Choosing energy sources with lower emissions, such as renewable energy, can help reduce the environmental impact of operating air compressors.
Proper Waste Management:
Proper waste management is essential when using air compressors. This includes the appropriate disposal of compressor lubricants, filters, and other maintenance-related materials. It is important to follow local regulations and guidelines for waste disposal to prevent contamination of soil, water, or air and minimize the environmental impact.
Sustainable Practices:
Adopting sustainable practices can further reduce the environmental impact of using air compressors. This can include implementing preventive maintenance programs to optimize performance, reducing idle time, and promoting responsible use of compressed air by avoiding overpressurization and optimizing system design.
By considering these environmental factors and taking appropriate measures, it is possible to minimize the environmental impact associated with the use of air compressors. Choosing energy-efficient models, addressing air leaks, managing waste properly, and adopting sustainable practices can contribute to a more environmentally friendly operation.
.webp)
What is the role of air compressor tanks?
Air compressor tanks, also known as receiver tanks or air receivers, play a crucial role in the operation of air compressor systems. They serve several important functions:
1. Storage and Pressure Regulation: The primary role of an air compressor tank is to store compressed air. As the compressor pumps air into the tank, it accumulates and pressurizes the air. The tank acts as a reservoir, allowing the compressor to operate intermittently while providing a steady supply of compressed air during periods of high demand. It helps regulate and stabilize the pressure in the system, reducing pressure fluctuations and ensuring a consistent supply of air.
2. Condensation and Moisture Separation: Compressed air contains moisture, which can condense as the air cools down inside the tank. Air compressor tanks are equipped with moisture separators or drain valves to collect and remove this condensed moisture. The tank provides a space for the moisture to settle, allowing it to be drained out periodically. This helps prevent moisture-related issues such as corrosion, contamination, and damage to downstream equipment.
3. Heat Dissipation: During compression, air temperature increases. The air compressor tank provides a larger surface area for the compressed air to cool down and dissipate heat. This helps prevent overheating of the compressor and ensures efficient operation.
4. Pressure Surge Mitigation: Air compressor tanks act as buffers to absorb pressure surges or pulsations that may occur during compressor operation. These surges can be caused by variations in demand, sudden changes in airflow, or the cyclic nature of reciprocating compressors. The tank absorbs these pressure fluctuations, reducing stress on the compressor and other components, and providing a more stable and consistent supply of compressed air.
5. Energy Efficiency: Air compressor tanks contribute to energy efficiency by reducing the need for the compressor to run continuously. The compressor can fill the tank during periods of low demand and then shut off when the desired pressure is reached. This allows the compressor to operate in shorter cycles, reducing energy consumption and minimizing wear and tear on the compressor motor.
6. Emergency Air Supply: In the event of a power outage or compressor failure, the stored compressed air in the tank can serve as an emergency air supply. This can provide temporary air for critical operations, allowing time for maintenance or repairs to be carried out without disrupting the overall workflow.
Overall, air compressor tanks provide storage, pressure regulation, moisture separation, heat dissipation, pressure surge mitigation, energy efficiency, and emergency backup capabilities. They are vital components that enhance the performance, reliability, and longevity of air compressor systems in various industrial, commercial, and personal applications.


editor by CX 2023-11-14